P12s Near-end severely ES threshold crossing 24-hrs egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SNSESgcTHR24
Information The P12s near-end severely errored seconds counter exceeded the provisioned
threshold during a 24-hours monitoring period (SDH ->PDH).
Alarm category Quality of service (performance monitoring)
ASAP pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Cause Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-105