RPSIP 3: <user entered string>
...................................................................................................................................................................................................................................
Alarm identifier
RPSMDcIP3
Information The Miscellaneous Discrete Input (MDI) number 2, located on the remote
power supply box, indicates an environmental alarm condition.
Alarm category Environment
ASAP mdi
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
Cause Alarm condition of co-located equipment.
Actions The measures to be taken depend on the specific application of the respective
MDI.
Note(s) MDIs can be used to monitor co-located equipment, a temperature sensor, for
example. MDIs can thus be used to trigger the reporting of application-specific
environmental alarms.
Each MDI can be assigned a descriptive text identifying the type of
environmental alarm condition in more detail.