SDSL Not expected input signal
...................................................................................................................................................................................................................................
Alarm identifier SDSLcNES
Information An incoming SDSL signal detected on a line- or tributary unit which was
provisioned “Not monitored”.
Alarm category Transmission
ASAP sdsl
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
Cause There are two possible reasons:
1. Either the port is intentionally not in use, and therefore is provisioned “Not
Monitored”, but mistakenly an input signal is applied (due to erroneous
routing of intermediate cabling for example), or
2. although an input signal is applied, the port is mistakenly provisioned “Not
Monitored”.
Actions Put the port in “Monitored”- state or check intermediate cabling.
Alarm messages
...................................................................................................................................................................................................................................
1-130
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007