SHDSL Near-end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
SDSLNSEScTHR24
Information The SHDSL near-end severely errored seconds counter exceeded the
provisioned threshold during a 24-hour monitoring period.
Alarm category Transmission
ASAP sdsl
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications –
Cause Severely Degraded connection - More SES than the allowed threshold (20)
have been detected in the current 24-hour bin.
Actions Check SHDSL connection on attenuation and crosstalk.
Note(s) The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.