STM-1 MS Near-end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier MS1NSEScTHR24
Information The STM-1 Multiplex Section near-end severely errored seconds counter
exceeded the provisioned threshold during a 24-hour monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications –
Cause Possible causes are:
• Dirty optical connector(s).
• Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
1-178
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2