STM-4 MS Moderate block error rate
...................................................................................................................................................................................................................................
Alarm identifier
MS4cDEG
Information STM-4 signal degrade. The block error rate of an incoming STM-4 signal
exceeds an error threshold. The signal degrade threshold can be provisioned via
the management system.
Alarm category Transmission
ASAP sdhMS
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
Cause Fault(s) in upstream external cabling or equipment.
Actions Check upstream external cabling and equipment.