STM-4 MS Near-end errored seconds threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier MS4NEScTHR24
Information The STM-4 Multiplex Section near-end errored seconds counter exceeded the
provisioned threshold during a 24-hour monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
Cause Possible causes are:
Dirty optical connector(s).
Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.