STM-4 MS Near-end unavailable seconds threshold crossing
15-min
...................................................................................................................................................................................................................................
Alarm identifier MS4NUAScTHR15
Information The STM-4 Multiplex Section near-end unavailable seconds counter exceeded
the provisioned threshold during a 15-minute monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
Cause Possible causes are:
Dirty optical connector(s).
Fiber cut.
Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
1-196
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007

Table of Contents

Other manuals for Alcatel-Lucent 1643 AMS