System timing in backup state
...................................................................................................................................................................................................................................
Alarm identifier TBACKcUPM
Information System timing switched to backup timing source.
Alarm category Transmission
ASAP timing
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
Cause No timing sources with sufficient quality and/or priority are present.
Actions Restore original timing source or reconfigure the most reliable timing source.