TU-3 Loss of pointer
...................................................................................................................................................................................................................................
Alarm identifier TU3cLOP
Information No valid tributary unit pointer interpretation obtained in received signal.
Alarm category Transmission
ASAP sdhLOPath
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications –
Cause Unit failure in the upstream node that generated the tributary unit pointer or in
the node that reported the alarm.
Actions Check on the management system if unit failure is reported for the unit
generating the tributary unit pointer.
In that node, remove the unit and replace it with a new one.
When unit failure is not reported, loop the STM-n signal at the transmitting
node and at the receiving node. In this condition, the node reporting TU-3 Loss
of pointer contains the faulty unit.
Note(s) In the upstream direction, “VC-3 Remote Defect Indicator” is activated.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-209