EasyManua.ls Logo

Alcatel-Lucent 1643 AMS - Alarm supervision concepts

Alcatel-Lucent 1643 AMS
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VC-11 Near- end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier VC11NSEScTHR24
Information The VC-11 near-end severely errored seconds counter exceeded the provisioned
threshold during a 24-hour monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
Cause Possible causes are:
Dirty optical connector(s).
Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-217

Table of Contents

Other manuals for Alcatel-Lucent 1643 AMS