VC-11 Near- end unavailable seconds threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier VC11NUAScTHR24
Information The VC-11 near-end unavailable seconds counter exceeded the provisioned
threshold during a 24-hour monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
Cause Possible causes are:
Dirty optical connector(s).
Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.