VC-11 Network connection server signal fail
...................................................................................................................................................................................................................................
Alarm identifier VC11cSSF
Information This alarm signals that the network connection is unavailable due to faults in
the serving higher order path and/or section layers.
Alarm category Transmission
ASAP sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
Cause One or more STM-1, MS, or VC-4 faults in this or upstream nodes, the effect
of which could not be circumvented via protection.
Actions When the VC-11 is unprotected, then select an alternative VC-4 as server for
the lower order VC.
When the VC-11 is protected, then check for external switch commands
locking the protection switch to a failed link connection.