VC-12 Unequipped
...................................................................................................................................................................................................................................
Alarm identifier VC12cUNEQ
Information VC-12 in STM-N signal not in use.
Alarm category Transmission
ASAP sdhLOPath
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications –
Cause Cross-connection not consistently defined at both sides (for example, at local
and remote station) of a line section.
Actions Define or change the cross-connection at the other side consistently with the
local side.
Note(s) When defining or changing a cross-connection this alarm will almost inevitably
come up as it is practically impossible to issue the changes simultaneously at
both sides.