WAN Dropped packets threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier WANDPcTHR24
Information The counter for the number of dropped packets at the WAN side
exceeded the provisioned threshold during a 24-hour monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP ethPath
Alarm severity (default
setting)
Information
Reporting state (default
setting)
Not Reported
Local indications
Cause Possible causes are:
Dirty optical connector(s)
Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Note(s) The counter only includes packets dropped due to errors. It does not
include packets dropped due to congestion.