X21 interface interface not expected input signal
...................................................................................................................................................................................................................................
Alarm identifier X21cNES
Information An incoming signal has been detected on an X.21 interface port although the
port is provisioned “Not Monitored”.
Alarm category Transmission
ASAP ethPS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications –
Cause There are two possible reasons:
1. Either the port is intentionally not in use, and therefore is provisioned “Not
Monitored”, but mistakenly an input signal is applied (due to erroneous
routing of intermediate cabling for example), or
2. although an input signal is applied, the port is mistakenly provisioned “Not
Monitored”.
Actions Put the X.21 interface port “Monitored”, or check the cabling (and re-arrange
if necessary).
Alarm messages
...................................................................................................................................................................................................................................
1-324
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007