X21 output timing mode change
...................................................................................................................................................................................................................................
Alarm identifier X21OTMcSW
Information The output timing mode of the affected 2 Mbit/s X.21 port has automatically
been switched from the re-timed to the self-timed mode.
Alarm category Transmission
ASAP ethPS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications –
Cause The quality of the system clock is not sufficient for re-timing purposes, and
therefore the output timing mode has automatically been switched from the
re-timed to the self- timed mode.
Actions Restore the original timing source, or reconfigure the most reliable timing
source to improve the quality of the system clock.