X21 output timing mode change
...................................................................................................................................................................................................................................
Alarm identifier X21OTMcSW
Information The output timing mode of the affected 2 Mbit/s X.21 port has automatically
been switched from the re-timed to the self-timed mode.
Alarm category Transmission
ASAP ethPS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
Cause The quality of the system clock is not sufficient for re-timing purposes, and
therefore the output timing mode has automatically been switched from the
re-timed to the self- timed mode.
Actions Restore the original timing source, or reconfigure the most reliable timing
source to improve the quality of the system clock.