1.5 Mbit/s ext board failure
...................................................................................................................................................................................................................................
Alarm identifier
E11XcEQF
Information The 1.5 Mbit/s extension board (X16DS1) is defective.
Alarm category Equipment
ASAP equipment
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
Cause The on board self-test circuitry indicates that an essential function of the unit
has failed.
Actions Replace the 1.5 Mbit/s extension board.
Note(s) As there is no equipment protection of the 1.5 Mbit/s extension board,
E11XcEQF and E11XcUPF are always reported simultaneously as a reminder
that a hardware failure is service affecting.