2 Mbit/s Excessive FAW bit error rate
...................................................................................................................................................................................................................................
Alarm identifier
P12ScEXC
Information 2 Mbit/s signal degrade protected. The block error rate of an incoming 2
Mbit/s signal exceeds an error threshold in a protected configuration (PDH ->
SDH).
Alarm category Transmission
ASAP
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
Cause Fault(s) in upstream external cabling or equipment.
Actions Check upstream external cabling and equipment.
Note(s) Threshold is not provisionable.