2 Mbit/s extension board failure - protected
...................................................................................................................................................................................................................................
Alarm identifier
E12XcEQF
Information The 2 Mbit/s extension board is defective.
Alarm category Equipment
ASAP equipment
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications The red “Fault” LED is lit.
Cause The on board self-test circuitry indicates that an essential function of the unit
fails.
Actions Replace the 2 Mbit/s extension board.
Note(s) As 1643 AM and 1643 AMS systems do not support hardware protection,
E12XcEQF, and E12XcUPF are always reported simultaneously as a reminder
that a hardware failure is service affecting.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-27