Ethernet interface Auto Negotiation Mismatch
...................................................................................................................................................................................................................................
Alarm identifier
LANcANM
Information A mismatch has been detected between the technology used for the local and
remote Ethernet equipment.
Alarm category Transmission
ASAP ethPS
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
Cause The auto-negotation function has failed to find a common technology with the
remote Ethernet equipment. This common technology can be 10Base-T half
duplex, 10Base-T full duplex, or 100Base-T half duplex.
Actions Force manually either or both ends of the link into a specific common
technology.
Note(s) When the auto-negotiation function is disabled, then the common technology
used is 10Base-T half duplex.
The common technology also depends on the type of Ethernet interface. On
optical Ethernet interfaces for example, always Gigabit Ethernet in full duplex
mode (1000Base-X full duplex) is assumed.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-53