EasyManua.ls Logo

Alcatel-Lucent 1643 AMS - Change the lock state

Alcatel-Lucent 1643 AMS
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISDN-PRA Loopback inband activated from far-end exchange
termination
...................................................................................................................................................................................................................................
Alarm identifier ISDNcLBK
Information ISDN-PRA Loopback inband activated from far- end exchange termination
Alarm category Processing error
ASAP pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications The red fault LED is lit.
Cause Loopback has been enabled via SC-manager or Sa-bits for the ISDN interface.
Actions Disconnect the loopback local or disconnect the loopback remote from far end.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page