SHDSL interfaces (X12SHDSL-V2 card)
...................................................................................................................................................................................................................................
Purpose
NOTE: A X12SHDSL-V2 card cannot be used in an AC powered AM unit.
The 1643 AM/AMS unit can act as an SHDSL LTU when it is equipped with the
X12SHDSL-V2 option card. SHDSL tributaries can be connected to these interfaces.
Connector data
The SHDSL connectors which are located on the X12SHDSL-V2 option card are RJ45
connectors.
Table 4-13 Pin assignment (SHDSL cables)
Point on Connector Signal Name
1nc
2nc
3nc
4 Tip [UKS1/a]
5 Ring [UKS1/b]
6nc
7nc
8nc
Cable data
Standard telephony cables can be used (see table below).
Be aware of the following two cases:
• If the cables are going to a distribution frame, an appropriate breakout cable can be
used (e.g. 16x2).
• If the cables are connected directly to modems, 2x2 cables can be used where only
one pair is required.
Figure 4-38 SHDSL connector
1
8
System cabling
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
4-37