STM-1e interfaces (X2STM1ETRIB card)
...................................................................................................................................................................................................................................
Purpose
STM-1 electrical inputs and outputs can be connected to these interfaces.
NOTE: The X2STM1ETRIB card can be used only for 1643 AM units which are
equipped with STM-4 interfaces.
Connector data
The STM-1e connectors which are located on the X2STM1ETRIB option card are DIN
1.6/5.6 coaxial connectors (75 , male).
Cable data (75 , coaxial)
Table 4-17 Components (STM-1e cable)
Component Part Number
1.0/2.3 straight crimp
plug, push pull
ITT Canon: D55-F24-
3035GDA
ITT Canon: D55-F24-3080GDA
1.0/2.3 75 ohm coax Belden: BT3002 (H133T03) Nexans: NCX1
Cables available for order (75 )
The following pre-configured cables can be ordered:
STM-1e coax cable5m—CC408939205
STM-1e coax cable 10 m CC408939213
STM-1e coax cable 15 m CC408939221
STM-1e coax cable 20 m CC408939239
Cable connection
Please connect the STM-1e cables as shown in the figure below.
Figure 4-48 Cable design (STM-1e cable)
System cabling
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
4-47