NE login procedure
...................................................................................................................................................................................................................................
Overview
This section describes the login procedure to an NE.
Before you begin
Before starting the application, ITM-CIT, and login to an NE, make sure that
• the PC is connected to the NE (see section “Connecting the ITM-CIT to the NE”
(p. 6-10))
• the PC is rebooted at least once after software installation.
Initial login procedure
Complete the following steps to login to an NE:
...................................................................................................................................................................................................
1
Start the ITM-CIT application.
Result: The main ITM-CIT window appears.
...................................................................................................................................................................................................
2
Select File → NE Login → Login in the main menu.
Result: The NE Login window appears.
...................................................................................................................................................................................................
3
Select the correct COM port.Usually, this is COM1.
...................................................................................................................................................................................................
4
Select Edit to set the correct baudrate.
1643 AM/AMS do operate on a baudrate of 115k.
...................................................................................................................................................................................................
5
Select Login.
Result: The Password Required window appears.
...................................................................................................................................................................................................
6
Select the user role from the capability field.
Selectable user roles are:
• Admin (for ITM-CIT administration and configuration of an NE)
• Config (to configure an NE)
• View (only to view NE configuration).
Fill in the required password (if configured) and click
OK.
ITM-CIT installation and NE provisioning
...................................................................................................................................................................................................................................
6-12
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007