Result:
Requirement
LEDs on the 1643 AM/AMS:
Power: On
Fault: Off
PDH analyzer: No errors detected
Alarms reported on the ITM-CIT: “xxcNES”, y Mbit/s Not Expected Input
Signal
1
Notes:
1. Not Expected Input Signal alarm refer to Step 4.
...................................................................................................................................................................................................
8
Check if the slot and port number of the NES alarm source corresponds with the
physical position on the DDF to which the analyzer is connected.
...................................................................................................................................................................................................
9
Disconnect the incoming signal from the port under test.
...................................................................................................................................................................................................
10
Repeat this test for all present option card tributary ports.
Cleaning up
The following tasks must be performed to clean up the system:
• Reset the Alarm Reporting/Severity of the applicable NES alarm to default (Not
Reported).
• If an E3 or DS3 option board is installed and the TUG structure of CC1,1 has been
modified then return it to VC-12.
• Delete all cross-connections.
Stand-alone test procedures
PDH option card test
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
7-15
E ND OF STEPS
...................................................................................................................................................................................................