Result: A window appears allowing for the selection of the appropriate file to be
downloaded.
...................................................................................................................................................................................................
4
Browse to the folder where the NE software is stored. The NE software can be
downloaded either from floppies or from the hard drive in the PC. Select the file
containing the NE software and click
Open.
Result: The Software Download Progress Display window appears and the progress
of the software download is displayed.
To abort the NE software download click
Abort.
Switch the software stores of the NE
Proceed as follows to switch the software stores of a NE:
...................................................................................................................................................................................................
1
Determine whether the MIB (Management Information Base) is compatible with the
NE software. If the MIB is not compatible, the MIB cannot be retained and must be
provisioned again with new settings after the software switch.
...................................................................................................................................................................................................
2
Select Provisioning → Equipment → NE Software Configuration.
Result: The NE Software Configuration window appears with information about
the software currently stored in the active and backup store of the NE.
...................................................................................................................................................................................................
3
Click Edit.
Result: The Edit NE Software Configuration window appears. Check if the correct
software version is stored in the backup store. After the switch, this will be the
active software running the NE.
...................................................................................................................................................................................................
4
Fill in the Retain MIB check box if the information in the MIB should be saved. This
is only possible if the MIB is compatible with the NE software. Not retaining the MIB
means that the NE must be provisioned again with the new settings.
Click
Switch.
Result: A confirmation window appears.
...................................................................................................................................................................................................
5
Click Yes.
Installation trouble shooting
Installing the NE software
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
B-5
E ND OF STEPS
...................................................................................................................................................................................................