If... Then...
it is a DCM card, ensure that it is the correct compensation
distance.
...................................................................................................................................................................................................
3
If the inserted card is the incorrect type, remove the card and insert one that matches the
provisioned type for the slot.
If the provisioning is incorrect, then reconfigure to make the provisioning match the card:
CLI
1.
config slot
<shelf slot port>
state down(Enter this
command for all client ports on the card and then the network port.)
2.
config slot
<shelf slot>
state down
3. config slot
<shelf slot>
type empty
4. config slot
<shelf slot>
type
<correct type>
WEBUI
1. Select the slot of the desired card, and on the Card Properties window,
select
Out of Service in the Primary State field, and click Submit.
2. Click the Delete tab, select Delete this card, and click
Submit.
3. On the Provision Card window, select the desired card type in the
Provisioned Type field, and click
Submit.
If the provisioning is correct and the card is of a matching type, then there is an issue with
the card itself. Continue with Step 4.
...................................................................................................................................................................................................
4
Perform a warm reset of the card.
CLI config card card_type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
5
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
Trouble-clearing procedures
MISMATCH
MISMATCH (Card Mismatch)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-187

Table of Contents