At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a warm reset of the card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
2
Remove the pluggable module from the port on the card it is inserted in. Examine the
connector on the pluggable module and the receptacle connector on the card where the
pluggable module plugs into for any damage. If no damage is seen, reinsert the pluggable
module into its port.
...................................................................................................................................................................................................
3
Remove and replace the pluggable module with another unit of the same type, being
careful with the connected fiber jumpers. Refer to “Replacing an SFP Module” (p. 3-27).
...................................................................................................................................................................................................
4
Perform a cold reset of the card on the card where the pluggable module failure is raised.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
5
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
6
Replace the card. Refer to “Replacing System Components” (p. 3-20).
UNG/UNP
UNG/UNP
The OT port has detected a UNG or UNP at the MEP layer.
Trouble-clearing procedures
TRMTMOD
TRMTMOD (Pluggable Module Transmit Failure)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-331
E ND OF STEPS
...................................................................................................................................................................................................