Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.If
there are no faults against working facility/equipment:
...................................................................................................................................................................................................
1
Wait for the wait-to-restore timer to expire.
...................................................................................................................................................................................................
2
Determine which side is the working side and which side is the protection side.
CLI show aps
...................................................................................................................................................................................................
3
Display the protection group for the associated shelf/slot/port.
CLI config aps group group detail
WEBUI Select the port of the card, and click the Port tab.
...................................................................................................................................................................................................
4
Check the administrative state on the protection side client/line ports.
CLI show interface
WEBUI From the Equipment Tree, select the card, and select the desired port.
If the state is down, the switch may have been caused by user administrative provisioning.
...................................................................................................................................................................................................
5
Check for faults on the protection side card, or the protection side client/line ports.
CLI alm
...................................................................................................................................................................................................
6
If... Then...
faults are present, proceed to the appropriate procedure for
clearing the faults.
Trouble-clearing procedures
WKSWBK
WKSWBK (Automatic switch to working)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-354
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011