If... Then...
no faults are present, the switch may have occurred due to a
transient defect that has since cleared. The
action required to clear this condition depends
on whether or not there are outstanding
problems against the working
facility/equipment.
...................................................................................................................................................................................................
7
Initiate a manual switch to working.
CLI config aps group group manualSwitchtoWorking
...................................................................................................................................................................................................
8
Clear the manual switch.
CLI config aps group group clearSwitch
If there are faults against protection facility/equipment:
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
9
Resolve the fault(s) against protection facility/equipment.
...................................................................................................................................................................................................
10
Display the protection group for the associated shelf/slot/port.
CLI config aps group group detail
...................................................................................................................................................................................................
11
Initiate a lockout of protect.
CLI config aps group <group> lockout
Note: This results in a standing condition for the lockout itself (LOCKOUTOFPR).
Trouble-clearing procedures
WKSWBK
WKSWBK (Automatic switch to working)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-355
E ND OF STEPS
...................................................................................................................................................................................................