Result: The Alarm List is displayed. The Equipment Controller will have a
DBINVALID alarm active after the reboot has completed.
...................................................................................................................................................................................................
5
If... Then...
the Equipment Controller is new from the
factory,
continue with Step 6
the Equipment Controller has the current
desired
software,
proceed to Step 24.
...................................................................................................................................................................................................
6
Select the shelf and slot where the User Panel is located (slot 40). Click the plus sign and
select
OAMP.
Result: The Port Interface Settings window is displayed.
...................................................................................................................................................................................................
7
Enter a valid IP address in the IP Address field.
...................................................................................................................................................................................................
8
Select System in the Equipment Tree.
Result: The System Properties window is displayed.
...................................................................................................................................................................................................
9
Enter values in the NE Name and Loopback IP Address fields.
...................................................................................................................................................................................................
10
Select Administration > Networking > IP Routes.
Result: The IP Routes window is displayed.
...................................................................................................................................................................................................
11
Leave the fields on this window at their default values. Select the Advertise field. Click
Create.
Result: The Create Static IP Route window is displayed.
...................................................................................................................................................................................................
12
Click Apply.
...................................................................................................................................................................................................
13
Select Administration > Software > FTP Server.
Supporting procedures