Changing an NE from a Nonredundant to a Redundant Equipment Controller configuration Using
the WebUI
...................................................................................................................................................................................................
1
To check that the NE is running software of Release 1.1.0 or higher, select System in the
Equipment Tree.
Result: The System Properties window is displayed.
...................................................................................................................................................................................................
2
View the software version in the Active Software Release field.
...................................................................................................................................................................................................
3
Backup the NE's database (see “Backing Up a Database” (p. 3-13)).
...................................................................................................................................................................................................
4
Install the redundant Equipment Controller into the shelf in slot 18.
...................................................................................................................................................................................................
5
Wait a few minutes for the Equipment Controllers to synchronize.
...................................................................................................................................................................................................
6
Connect the Equipment Controller cables. Refer to the Alcatel-Lucent Product
Information and Planning Guide.
Changing an NE from a Nonredundant to a Redundant Equipment Controller Configuration Using
the CLI
...................................................................................................................................................................................................
1
To check that the NE is running software of Release 1.1.0 or higher, type sh version.
...................................................................................................................................................................................................
2
To backup the NE's database, see “Backing Up a Database” (p. 3-13).
...................................................................................................................................................................................................
3
Install the redundant Equipment Controller into the shelf in slot 18.
...................................................................................................................................................................................................
4
Wait a few minutes for the Equipment Controllers to synchronize.
Supporting procedures
Changing the Equipment Controller Configuration in an NE
Changing an NE from a Nonredundant to a Redundant
Equipment Controller Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-72
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................