Restoring an NE in DBINVALID State
During software upgrade (for example, R2.5.
n
to R3.0.2) if an RNE raises the
DBINVALID alarm, perform the steps in the following procedure to restore the NE.
...................................................................................................................................................................................................
1
From the active EC - CIT port get the NE Connectivity.
WEBUI In the Equipment Tree, select EC card > CIT port.
...................................................................................................................................................................................................
2
Check the software version. If the DBINVALID alarm was raised in R3.0.2 software, then
configure the software server setting.
CLI sh version
alm
...................................................................................................................................................................................................
3
Perform a software upgrade. Select Administration > Software > Upgrade.
Result: The Software Upgrade window is displayed.
CLI Enter the following commands:—
1.
config software server
Add the next applicable command to the string as follows:•
detail—Display software server information
•
ip—Configure the software download server IP address
•
protocol—Configure the software download protocol
•
userid—Configure the userid for accessing the software
download server
•
root—Configure the software server root directory
2. config software upgrade manual
Add the next applicable command to the string as follows:•
activate—Perform software activation steps as determined by
audit
•
audit—Determine steps needed to install chosen release
•
load—Perform software transfer steps as determined by audit
3. config software upgrade commit
WEBUI Do the following:
1. In the Action field, select
Audit. Enter the values in the path for the
release you want to upgrade to (for example, R2.5.
n
) in the Release
Directory field. Click
Apply.
2. In the Action field, select
Load. Click Apply.
3. In the Action field, select
Activate. Click Apply > Close.
...................................................................................................................................................................................................
4
Check the software version and confirm the NE is running R2.5 load
CLI show version
Supporting procedures
Software Upgrades
Restoring an NE in DBINVALID State
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011