OT port has detected Loss of 64B/66B or 8B/10B block/character synchronization on
10GbE, 1GbE or FC facility.
These conditions may be caused by the following reasons:
Damaged, cut or dirty fiber connected to the local receiver
Received power may not be within the acceptable range on local port input
Damaged or dirty transmitter inside pluggable module
Severity Critical
Service affecting? Yes
Applicability 11DPE12, 11DPE12E, 11QPA4, 11STAR1, 11STMM10,
11STGE12, 43STX4
Corrective Action
This procedure details the corrective action for clearing a LANLSS condition on an OT
port.
...................................................................................................................................................................................................
1
Retrieve power level reading on the local port.
...................................................................................................................................................................................................
2
Clean the fiber.
...................................................................................................................................................................................................
3
If cleaning the fiber does not clear the problem, replace the fiber.
...................................................................................................................................................................................................
4
If power level is within the operating range, check for pluggable module alarms.
...................................................................................................................................................................................................
5
If there is a pluggable module alarm present on the local port follow procedure for
detected alarm.
...................................................................................................................................................................................................
6
Replace the pluggable module.
LANRFI
Trouble-clearing procedures
LANLSS
LANLSS (Loss of Synchronization)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-123
E ND OF STEPS
...................................................................................................................................................................................................