Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Trace the source of the LINKDOWN condition to the associated card and port upstream.
Verify that the source is operationally up by checking the Admin state. If the Admin state
is Up, then toggle the administrative state from UP->DOWN->UP.
EMS Double-click the NE and then on the alarmed card's client receive port.
...................................................................................................................................................................................................
2
Remove the fiber from the port where the LINKDOWN condition is raised and clean the
fiber and the bulkhead connector.
...................................................................................................................................................................................................
3
Repeat Step 2 for the other end of the fiber and port where it is connected.
...................................................................................................................................................................................................
4
Replace the fiber jumper with a new one.
...................................................................................................................................................................................................
5
Perform a warm reset on the card that is the source of the Ethernet signal.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
6
Perform a warm reset on the card where the LINKDOWN condition is raised.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
Trouble-clearing procedures
LINKDOWN
LINKDOWN (Link down)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-130
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011