MANSWTIMREF
MANSWTIMREF (Timing selection was switched by a manual
command to a timing reference)
The MANSWTIMREF condition occurs when OT port detects MANSWTIMREF at the
LINEREF layer. A LINEREF detects MANSWTIMREF when the timing selection is
switched by a manual command to a timing reference.
Severity Minor
Service affecting? No
Applicability LINEREFSYS
Corrective Action
...................................................................................................................................................................................................
1
Clear manual switch.
CLI show card 11dpe12e
shelf/slot
synce
WEBUI Select the 11DPE12E card in the Equipment Tree.
Select System Timing.
MANSWTOINT
MANSWTOINT (Manual Switch to Internal Timing )
The OT port has detected a MANSWTOINT at the SYNC layer. A SYNC detects
MANSWTOINT when a manual switch to Internal Timing (forced Free-Running mode)
has occurred.
Severity NA
Service affecting? No
Applicability SYNC
Trouble-clearing procedures
MANSWTIMREF
MANSWTIMREF (Timing selection was switched by a manual
command to a timing reference)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-182
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................