3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-69
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Name: MisconfiguredInflow
Type: communicationsAlarm (4)
Probable cause: misconfiguredInflow (809)
Severity: Major
Object Type (class):
VlanPathInstance
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the ports in
a service use different inflow clock
sources.
Name: MprVllDown
Type: serviceDown (88)
Probable cause: vlanPathInstanceDown
(524)
Severity: Major
Object Type (class): MprVll
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
Operational State of a VLAN path
instance is Down, for example,
because of one of the following
conditions:
The radio link is down.
A cross connect is deleted.
The Operational State of one or
more ports in the cross connect
is Down.
Name: PhysicalLinkDown
Type: communicationsAlarm (4)
Probable cause: PhysicalLinkDown (846)
Severity: Major
Object Type (class): VlanPath
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the radio
link between two hops of a VLAN
path is down.
Name: PortsSeggregated
Type: communicationsAlarm (4)
Probable cause: portsSeggregated (522)
Severity: Major
Object Type (class):
VlanPathInstance
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the two
ports that are to be part of a service
cross-connect are segregated.
Name: RadioLinkDown
Type: communicationsAlarm (4)
Probable cause: radioLinkDown (523)
Severity: Major
Object Type (class): VlanPath
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the radio
link between two hops of a VLAN
path is down.
Name: RDI
Type: communicationsAlarm (4)
Probable cause: remoteDefectIndication
(572)
Severity: Minor
Object Type (class): IMALink
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when a Remote
Defect Indication signal is detected
on an ASAP MDA.
Name: VlanPathInstanceDown
Type: VlanPathInstanceAlarm (61)
Probable cause: vlanPathInstanceDown
(524)
Severity: Major
Object Type (class):
VlanPathInstance
Domain: mpr
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
Operational State of a VLAN path
instance is Down, for example,
because of one of the following
conditions:
The radio link is down.
A cross connect is deleted.
The Operational State of one or
more ports in the cross connect
is Down.
Alarm Attributes Additional information