3 — Troubleshooting using network alarms
3-82 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: TrapDestinationMisconfigured
Type: configurationAlarm (11)
Probable causes:
trapDestinationMisconfigured (26)
duplicateTrapLogId (27)
Severity: Major
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): Yes
The alarm is raised when an SNMP
trap destination other than the
5620 SAM is configured on an NE.
Name: TrapMalformed
Type: communicationsAlarm (4)
Probable cause: trapSchemaMismatch (108)
Severity: Major
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): No
The alarm is raised when the number
of varbinds in an incoming SNMP trap
is fewer than the number expected.
Name: TrapRateThresholdExceeded
Type: communicationsAlarm (4)
Probable cause:
trapRateGreaterThanConfigured (307)
Severity: Critical
Object Type (class): NmsSystem
Domain: netw
Implicitly cleared (self-clearing): No
The alarm is raised when the
incoming SNMP trap rate is greater
than the configured trap rate
threshold.
Name: TrapReceivingFailure
Type: communications (87)
Probable cause: trapsWillNotBeSent (822)
Severity: Major
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): No
This user-defined alarm is raised
when the NE is unable to send traps
because the NE configuration is one
of the following:
The Management IP Selection is
set to Out Of Band Only, the
Primary Route Preference is set
to In Band, and the Secondary
Route Preference is set to None.
The Management IP Selection is
set to In Band Only, the Primary
Route Preference is set to Out Of
Band, and the Secondary Route
Preference is set to None.
Name:
TrapRoutePreferenceRedundancyMissing
Type: communications (87)
Probable cause: trapsRedundancyMissing
(823)
Severity: Warning
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): Yes
The user-defined alarm is raised
when NE management redundancy is
configured without trap route
preference redundancy.
Name: UnmanageFailed
Type: discoveryControlAlarm (33)
Probable cause: unableToDeleteNode (231)
Severity: Warning
Object Type (class):
NodeDiscoveryControl
Domain: netw
Implicitly cleared (self-clearing): Yes
The alarm is raised when an attempt
to unmanage an NE fails.
Name: UnsupportedNode
Type: configurationAlarm (11)
Probable cause: unsupportedNode (219)
Severity: Warning
Object Type (class): Topology
Domain: netw
Implicitly cleared (self-clearing): No
The alarm is raised when, during
network discovery, the 5620 SAM
detects an NE that uses an
unsupported device software
version. The alarm information
includes the discovery rule ID and the
IP address of the NE.
Name: UpgradedBuildVersionMismatch
Type: configurationAlarm (11)
Probable cause: upgradedImageNotBooted
(137)
Severity: Warning
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
software version that an NE reports
after a software upgrade does not
match the version of the software
used for the upgrade.
Alarm Attributes Additional information
(10 of 11)