3 — Troubleshooting using network alarms
3-96 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Table 3-51 Domain: radioequipment
Alarm Attributes Additional information
Name: AtpcLoopProblem
Type: communicationsAlarm (4)
Probable cause: atpcLoopProblem (848)
Severity: Minor
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a receiver
protection switchover fails.
Name: BandwidthOverFlow
Type: communicationsAlarm (4)
Probable cause: bandwidthOverFlow (849)
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a receiver
protection switchover fails.
Name: CableLOS
Type: communicationsAlarm (4)
Probable cause: cableLOS (493)
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an MSS
detects a cable LOS event.
Name: CrossConnectionFail
Type: communicationsAlarm (4)
Probable cause: crossConnectionFail (494)
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an MSS TDM
cross-connection fails.
Name: DemFail
Type: communicationsAlarm (4)
Probable cause: demFail (495)
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an MSS
demodulation function fails.
Name: EarlyWarning
Type: communicationsAlarm (4)
Probable cause: earlyWarning (496)
Severity: Warning
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an MSS
detects an early warning event.
Name: HighBER
Type: communicationsAlarm (4)
Probable cause: highBER (497)
Severity: Minor
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an MSS
detects a high BER.
Name: IncompatibleFrequency
Type: communicationsAlarm (4)
Probable cause: incompatibleFrequency
(498)
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a
provisioned MSS frequency is
incompatible with the MSS hardware.
Name: IncompatibleModulationParam
Type: communicationsAlarm (4)
Probable cause: incompatibleModulation
(850)
Severity: Minor
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a receiver
protection switchover fails.
(1 of 2)