3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-117
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Table 3-66 Domain: snmp
Table 3-67 Domain: sonet
Alarm Attributes Additional information
Name: MediationAuthenticationFailure
Type: communicationsAlarm (4)
Probable cause: noMediationPolicyFound
(62)
Severity: Critical
Object Type (class): PollerManager
Domain: snmp
Implicitly cleared (self-clearing): No
The alarm is raised when an NE has
no associated 5620 SAM mediation
policy.
Alarm Attributes Additional information
Name: AllTimingReferencesNotQualified
Type: communicationsAlarm (4)
Probable cause:
allTimingReferencesNotQualified (419)
Severity: Major
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when no timing
references on an NE are in the
Qualified state.
Name: BITSNotQualified
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Severity: Minor
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BITS
timing reference on an NE is not in
the Qualified state.
Name:
ExternalTimingReferenceNotQualified
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Severity: Minor
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
External timing reference on an NE is
not in the Qualified state.
Name: SiteSyncDeploymentFailure
Type: equipmentAlarm (3)
Probable cause: siteSyncFailure (441)
Severity: Major
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): No
The alarm is raised when the
5620 SAM tries to deploy a value for
an object when a transaction that
involves the object is in progress
from a different context.
Name: TimingHoldover
Type: communicationsAlarm (4)
Probable cause: timingHoldover (511)
Severity: Major
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when the timing
of an NE is in the Holdover state.
Name: TimingReferenceOneNotQualified
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Severity: Minor
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when Timing
Reference One on an NE is not in the
Qualified state.
Name: TimingReferenceTwoNotQualified
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Severity: Minor
Object Type (class): SiteSync
Domain: sonet
Implicitly cleared (self-clearing): Yes
The alarm is raised when Timing
Reference Two on an NE is not in the
Qualified state.