Loading...
Point to Point Protocol
Left running head:
Chapter name (automatic)
300
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
Alcatel-Lucent
PPP TIMEOUT RESTART-TIMER
ppp timeout restart-timer <1-30>
DESCRIPTION
This command is entered in the Interface Configuration Mode. This command
sets a timer for re-transmission of LCP and NCP packets.
PARAMETERS
DEFAULT VALUE
The default restart-timer value is “3 seconds”.
EXAMPLE
ALU(config-if Serial0/0:0)# ppp timeout restart-timer 13
PPP TIMEOUT MAX-CONFIGURE
ppp timeout max-configure <1-30>
DESCRIPTION
This command is entered in the Interface Configuration Mode. This command
sets the maximum number of configure request packets (LCP or NCP) sent
without receiving a valid Ack/NaK/Reject, before assuming that the peer is unable
to respond.
PARAMETERS
DEFAULT VALUE
The default max-configure value is “10”.
EXAMPLE
ALU(config-if Serial0/0:0)# ppp timeout max-configure 15
Parameter Description
1-30 The timer for retransmission (in seconds) of LCP
and NCP packets. The range varies from 1-30.
Parameter Description
1-30 Maximum number of configure request packets
(LCP or NCP) to be sent without receiving a
valid Ack/NaK/Reject, before assuming that the
peer is unable to respond.