ETH-TEST TEST-PATTERN
eth-test test-pattern {all-ones|all-zeros} crc {enable|disable}
DESCRIPTION
This is entered in the OAM Domain Association MEP Configuration Mode. This
command is used to configure test pattern for Ethernet test signal on a MEP.
PARAMETERS
DEFAULT VALUE
By default, the test pattern is all 0's and no CRC.
PLATFORMS SUPPORTED
OmniAccess 5740 USG
EXAMPLE
ALU(config-oam-domain-assoc-mep)# eth-test test-pattern all-
ones crc enable
RELEASE HISTORY
Release 3.0: command was introduced.
Parameter Description
all-ones Indicates to send all 1's in the test
pattern.
all-zeros Indicates to send all 0's in the test
pattern.
enable|disable Enable/disable CRC (Cyclic