17 L2 VFL LACP Down -> Up 4 00:45:56 INFO_03
18 L3 VCM Protocol Role (@L5) Slave 00:40:45 OK
19 L3 VCM Protocol Role Master 01:03:57 OK
20 L3 VCM Protocol Status (@L5) Running 00:40:45 OK
21 L3 VCM Protocol Status Running 01:03:57 OK
24 L4 VCM Connection Up 01:03:57 OK
25 L4 VCM Connection (@L5) Up 00:40:45 OK
26 L5 VCM Synchronization Multi-node 01:03:57 OK
27 L6 Chassis Sup Connection Up 00:46:00 OK
28 L6 Remote Flash Mounted Yes 00:46:26 OK
29 L6 Image and Config Checked Yes 00:41:01 OK
30 L6 VC Takeover Sent Yes 00:42:55 OK
31 L7 VC Takeover Acknowledged Yes 00:42:58 OK
32 L8 System Ready Received Yes 00:41:06 OK
33 L8 RCD Operational Status N/A N/A N/A
34 L8 RCD IP Address N/A N/A N/A
Error/Information Codes Detected:
--------------------------------------------------------------------------------
NOK_08
There are no virtual-fabric member ports configured on this switch.
If there are multiple virtual-fabric links configured, we must have
at least one member port configured or assigned to each of the
virtual-fabric links.
Troubleshooting Tips:
-> show virtual-chassis vf-link member-port | grep "<local-chassis-id>/"
NOK_09
There are no virtual-fabric member interfaces operationally up.
If there are multiple virtual-fabric links configured, we must have
at least one member port interface up on each virtual-fabric link.
Troubleshooting Tips:
-> show virtual-chassis vf-link member-port | grep "<local-chassis-id>/"
-> show interfaces port <chassis>/<slot>/<port> status
NOK_09
There are no virtual-fabric member interfaces operationally up.
If there are multiple virtual-fabric links configured, we must have
at least one member port interface up on each virtual-fabric link.
Troubleshooting Tips:
-> show virtual-chassis vf-link member-port | grep "<local-chassis-id>/"
-> show interfaces port <chassis>/<slot>/<port> status
NOK_14
The virtual-fabric links configured on this switch are not operationally up.
If there are multiple links configured, all of them must be operationally up
in order for this parameter to be reported as OK.
Troubleshooting Tips:
-> show virtual-chassis vf-link | grep "<local-chassis-id>/"
NOK_14
The virtual-fabric links configured on this switch are not operationally up.
If there are multiple links configured, all of them must be operationally up
in order for this parameter to be reported as OK.
Troubleshooting Tips:
-> show virtual-chassis vf-link | grep "<local-chassis-id>/"
INFO_04
This parameter provides the counter of how many times the
virtual-fabric link operational status has transitioned from
up to down since the switch was started. Depending on the specific
operations you are performing on the system, this counter may
increase. Under normal conditions this counter should ideally
be one unit smaller than the counter for the opposite transitions
from operational down to up
INFO_03
This parameter provides the counter of how many times the
virtual-fabric link operational status has transitioned from
down to up since the switch was started. Depending on the specific
operations you are performing on the system, this counter may

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 10K

Related product manuals