OmniSwitch OS6860/OS6900/OS10K Troubleshooting Guide Part No.032996-00 Rev.A
AOS Release 7.X and 8.X January 2015
Alcatel-Lucent Page 25 of 148
Chas* ID Status Type* Group* Interv Vlan* Vlan License*
------+------+---------+-------+------+-------+--------+--------+----------
1 1 OK OS6860 0 15 4094 4094
2 2 OK OS6860 0 15 4094 4094
3 3 OK OS6860 0 15 4094 4094
4 4 OK OS6860 0 15 4094 4094
5 5 OK OS6860 0 15 4094 4094
6 6 OK OS6860 0 15 4094 4094
To check IPC (inter-switch) connectivity:
Ping 127.10.2.65 // CMM-A on Chassis 2
Ping 127.10.2.1 // NI-1 on Chassis 2
To check all the inter-switch connectivity.
To lookup a MAC address and see if it is learned on the hardware
To display all the MACs learned on the hardware:
OS6860-10.255.13.68-> su
Entering maintenance shell. Type 'exit' when you are done.
SHASTA #-> bShell
BCM.0> l2 show
mac=e8:e7:32:b3:45:cd vlan=100 modid=0 port=0/cpu0 Static Hit CPU
mac=00:0a:1e:22:07:f8 vlan=4094 modid=24 port=0 Hit
mac=00:0a:1e:22:02:51 vlan=4094 modid=4 port=0 Hit
mac=00:0a:1e:22:06:f8 vlan=4094 modid=20 port=0 Hit
mac=00:0a:1e:22:03:51 vlan=4094 modid=8 port=0 Hit
……
To verify inter-process communication between switches.
SHASTA #-> ping -c 10 -s 400 -f 127.10.2.65
PING 127.10.2.65 (127.10.2.65) 400(428) bytes of data.
--- 127.10.2.65 ping statistics ---
10 packets transmitted, 10 received, 0% packet loss, time 24ms
rtt min/avg/max/mdev = 0.556/2.412/9.297/2.984 ms, ipg/ewma 2.759/3.191 ms
To check if the VCM process was able to establish inter-chassis ipc connections
OS6860-10.255.13.68-> debug show virtual-chassis connection
Address Address
Chas MAC-Address Local IP Remote IP Status
-----+------------------+-----------------+-----------------+-------------
2 e8:e7:32:b3:3c:3b 127.10.1.65 127.10.2.65 Connected
3 e8:e7:32:b3:34:cd 127.10.1.65 127.10.3.65 Connected
4 e8:e7:32:b3:49:11 127.10.1.65 127.10.4.65 Connected
5 e8:e7:32:ab:21:b9 127.10.1.65 127.10.5.65 Connected
6 e8:e7:32:b3:3b:ef 127.10.1.65 127.10.6.65 Connected
7 e8:e7:32:ab:1c:d3 127.10.1.65 127.10.7.65 Connected
The above command will also show the internal ip address for every switch in the virtual-chassis.
Remote Chassis Detection (RCD) occurs every 1 seconds between the switches in the virtual chassis when the
EMP ports are configured.
OS6860-10.255.13.68-> show virtual-chassis vf-link member-port
Chassis/VFLink ID Chassis/Slot/Port Oper Is Primary