OmniSwitch OS6860/OS6900/OS10K Troubleshooting Guide Part No.032996-00 Rev.A
AOS Release 7.X and 8.X January 2015
Alcatel-Lucent Page 76 of 148
10.3. Advanced troubleshooting
Dislay QoS rules configured in TCAM
In a VC chassis id needs to be specified, for example: debug qos internal "chassis 1 slot 1 list
1 verbose"
In AOS 7.3.3.R01 use "slot 0/1 list 0 verbose" or "chassis 0 slot 1 list 0 verbose"
All lists:
-> debug qos internal "slot 1 list 255 verbose"
Entry U Slice CIDU CIDL MIDU MIDL TCAM Count[+] Green[+]
Red[+] NotGreen[+]
List 0 empty
List 1: 19 entries set up
McastARP( 17) 0 8 1543 - - - 1636 0[0 ] 0[0 ]
0[0 ] 0[0
McastARP( 17) 0 9 - - - - 1892 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU1( 22) 0 8 - 1536 - - 1590 10738[10738 ] 0[0 ]
0[0 ] 0[0
...
List 0 (user rules):
-> debug qos internal "slot 1 list 0 verbose"
Entry U Slice CIDU CIDL MIDU MIDL TCAM Count[+] Green[+]
Red[+] NotGreen[+]
List 0: 1 entries set up
Policy( 0) 0 7 - 1280 - - 1280 0[0 ] 0[0 ]
0[0 ] 0[0
List 1 (all copy to CPU):
-> debug qos internal "slot 1 list 1 verbose"
Entry U Slice CIDU CIDL MIDU MIDL TCAM Count[+] Green[+]
Red[+] NotGreen[+]
List 1: 20 entries set up
HgMcastARP( 16) 0 -1 - - 0 0 -2 0[0 ] 0[0 ]
0[0 ] 0[0
McastARP( 17) 0 8 1543 - - - 1636 0[0 ] 0[0 ]
0[0 ] 0[0
McastARP( 17) 0 9 - - - - 1892 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU1( 22) 0 8 - 1536 - - 1590 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU1( 22) 0 9 - - - - 1846 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU2( 23) 0 8 1537 - - - 1591 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU2( 23) 0 9 - - - - 1847 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU3( 24) 0 8 - 1538 - - 1592 0[0 ] 0[0 ]
0[0 ] 0[0
ISIS_BPDU3( 24) 0 9 - - - - 1848 0[0 ] 0[0 ]
0[0 ] 0[0
IPMS_IGMP( 50) 0 8 1539 - - - 1638 576[0 ] 0[0 ]
0[0 ] 0[0
IPMS_IGMP( 50) 0 9 - - - - 1894 576[0 ] 0[0 ]
0[0 ] 0[0
IPMS_V4Control( 51) 0 8 - 1540 - - 1639 1829[5 ] 0[0 ]
0[0 ] 0[0
IPMS_V4Control( 51) 0 9 - - - - 1895 1829[0 ] 0[0 ]
0[0 ] 0[0
IPMS_V4Data( 52) 0 8 1541 - - - 1640 0[0 ] 0[0 ]
0[0 ] 0[0
IPMS_V4Data( 52) 0 9 - - - - 1896 0[0 ] 0[0 ]
0[0 ] 0[0