Mounting OS6250 Switches Connecting Chassis to Power Source
OmniSwitch 6250 Series Hardware Users Guide September 2009 page 3-21
Preliminary
9/28/09
Connecting Chassis to Power Source
AC Power Supply Connections
Since the power cord is the switch’s only disconnect device, it should be plugged into an easily accessible
outlet. In the event that your power cord is lost or damaged, refer to the specifications below.
Powering On a Chassis
Follow the steps below to power on the chassis using and AC power source:
1 Connect the IEC-60320-C15 end of the supplied power cord to the primary and optional redundant
power supply.
2 Install one cord retainer bracket to the back of each installed power supply using the attachment screws
(provided). Once all retainer clips are attached, place the slotted retainer clip over the bracket with the
retainer fingers pointing down and slide the retainer bracket toward the power supply until it meets the
power cord connector. Insert two screws (provided) into the retainer clip slots and tighten until secure.
3 Connect primary and optional redundant power supplies to AC power source.
4 Monitor the chassis as it boots.
Retainer bracket
Slotted retainer clip
Power cord connector
Power supply