Chassis Management and Monitoring Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 2-51
show temperature
Displays the current operating chassis ambient temperature, as well as current temperature threshold
settings.
show temperature [number]
Syntax Definitions
number Specifies the slot (i.e., switch) number within the stack. The valid range
of slot numbers is 1–8, depending on the size of the stack.
Defaults
If a slot number is not specified with this command, temperature information for all switches operating in
the stack is displayed by default.
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The number parameter is not an option when using this command on a standalone switch.
Examples
-> show temperature
Temperature for chassis 1
Hardware Board Temperature (deg C) = 41,
Hardware Cpu Temperature (deg C) = N/A,
Temperature Upper Threshold Range (deg C) = 15 to 80,
Temperature Upper Threshold (deg C) = 57,
Temperature Status = UNDER THRESHOLD,
Temperature Danger Threshold (deg C) = 80
Temperature for chassis 2
Hardware Board Temperature (deg C) = 40,
Hardware Cpu Temperature (deg C) = N/A,
Temperature Upper Threshold Range (deg C) = 15 to 80,
Temperature Upper Threshold (deg C) = 57,
Temperature Status = UNDER THRESHOLD,
Temperature Danger Threshold (deg C) = 80
Temperature for chassis 3
Hardware Board Temperature (deg C) = 40,
Hardware Cpu Temperature (deg C) = N/A,
Temperature Upper Threshold Range (deg C) = 15 to 80,
Temperature Upper Threshold (deg C) = 57,
Temperature Status = UNDER THRESHOLD,
Temperature Danger Threshold (deg C) = 80