RIP Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 33-19
ip rip update-interval
Configures the time interval during which RIP routing updates are sent out.
ip rip update-interval seconds
Syntax Definitions
seconds The RIP routing update interval, in seconds. The valid range is 1–120.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The update interval value must be less than or equal to one-third the invalid interval value.
Examples
-> ip rip update-interval 45
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
alaProtocolRip
alaRipUpdateInterval
parameter default
seconds 30
show ip rip Displays the RIP status and general configuration parameters (e.g.,
forced hold-down timer).