RIP Commands
page 33-22 OmniSwitch 6250 CLI Reference Guide November 2009
ip rip holddown-timer
Configures the RIP hold-down timer value that defines the time interval during which a route remains in
the hold-down state.
ip rip holddown-timer seconds
Syntax Definition
seconds The hold-down time interval, in seconds. The valid range is 0–120.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
When RIP detects a route with higher metric than the route in the RIB, the route with the higher metric
goes into the hold-down state. The route updates with a metric of INFINITY are rejected.
Examples
-> ip rip holddown-timer 10
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
alaProtocolRip
alaRipHolddownTimer
parameter default
seconds 0
show ip rip Displays the RIP status and general configuration parameters (e.g.,
forced hold-down timer).